GR-1 |
SB-2(A) |
SB-3
NEW! |
SB-T |
|
|
|
The GR-1 is a precision time code generator/reader designed for production sound recording. The GR-1 can be used as a stand-alone master time code source in most recording environments. Low power consumption with back lighting assures users of long battery life in a small reliable package. Speed checking, memory hold and print are powerful features that will help sound mixers on the set.
|
|
 |
|
READ - Reads SMPTE/EBU time code at normal operating speeds. |
|
GX - Generates time code locked to an external field or frame reference. |
|
DISPLAY - Displays time code/user bits and mode on a low power LCD backlit display. |
|
GU - Inserts externally read time code into the user bits of the current time code. This is useful for music playback with live action recording. |
 |
RATE - Displays the incoming time code speed, mode and drop frame status. |
 |
CLOCK - An internal time of day clock updates the code on every power up. |
 |
HOLD - Saves hold points in memory. Previous time code/user bit points are shown along with their memory location. |
 |
JAM - Jam syncs to external code and can cross jam different code rates. Any break in code will jam to a new value (continuous jam). |
 |
GEN - Generates time code at 23.976, 24, 25, 29.97, 30 fps drop and non drop. User bits can be left free or set as date in the month/day or day/month format. |
 |
CHECK - Displays a comparison of the internal time code to external time code. An =, ¹, + or - sign in the jam, generate and start/stop modes show offset and drift. |
 |
REMOTE - Printer out, hold start/stop and TC in/out are accessible in the 9 pin "D" connector. |
 |
PRINT - A serial printer can be connected to make time code logs, read breaks in input code and print stored memory points. |
|
SS - Generates time code in the start/stop mode. The code is normally stopped until pin #2 of the remote connector is pulled low. The hold memory is updated with every code start point. |
|
LB - Indicates low battery before the power is exhausted. Also displays status of the internal memory battery. |
|
|
|
|
|
|
SIZE & WEIGHT: 5.9" x 4.25" x 1.55", 1.3 lbs. |
|
OUTPUT: 2 volts into 1k load impedance |
|
PRINTER: Serial out 1200 baud 8 bits 5 volt with DTR. |
|
STABILITY: High stability TCXO crystal. +/- 1ppm -30 to +75°C |
|
INPUT: Reads code down to -18db with 51k input impedance |
|
POWER: 6 to 24v DC at 15ma (backlight off) 25ma (backlight on). 6 AA internal battery supply. Battery life approximately 70 hours. 1 BR2325 3v memory backup. Battery life approximately 1 year. |
|
|
|
|
|
|
|
| |
|
|
|
The Dcode Syncbox Time Code Generator is designed to work with the Dcode Time Code Slate allowing complete freedom from cables. It is great for concerts where transmitted time code is not feasible. The Syncbox generates all common time code formats. It can be jam set from an external time code source or internally set and used as a stand-alone generator.
Generates 23.976 fps for High Definition Cameras!
NOTE: SB-2(A) is no longer available due to obsolete chips on the motherboard. Spare and replacement parts for the SB-2(A) will continue to be available, but new units are no longer in production.
|
|
 |
|
Generates time code at: 23.976, 24, 25, 29.97 and 30 fps 29.97, 30 drop frame. |
 |
PRINTER I/O for logging with take numbers or for a computer serial interface
|
|
Generates Sync Pulse at: 50, 59.94, and 60 Hz squarewave; optional 48 Hz squarewave. |
 |
EXTERNAL REMOTE POWER and TC Loop through |
|
TIME CODE SET: Minutes can be set only in the local mode. Pushing the button increments the minutes. Holding the button increments the minutes at a fast rate, useful for setting UB hours. Minute set is inhibited after 10 minutes. |
 |
TIME CODE IN: The generator is jam set at power on. Both time code and user bits are set from the external source. In Jam mode the LED strobes once per second on the second at turn on. |
|
TIME CODE OUT: The local mode starts code at (00:58:30:00) allowing time to set hours before the rollover to the next hour.
User bits displayed in the local mode are (00:00:00:XX) where XX indicates the internal frame rate setting.
Example: (00:00:00:30) shows the generator is running at 30fps.
The user bit hour position automatically increments on the 24th hour.
Example: (01:00:00:30) shows on rollover.
The internal LED strobes at the selected frame rate for 10 minutes after turn on. The LED strobes once per second after that to conserve battery life.
|
|
|
|
|
|
|
|
|
SIZE & WEIGHT:
4.7" x 2.4" x 1.0"
4.7 oz. (no battery) |
 |
OUTPUT: 1 volt peak into a 10K OHM load.
|
|
BATTERY LIFE: Approximately 60 hours with an alkaline battery (Duracell MN1604). No damage with reverse battery. |
 |
POWER: 9 volts at 7ma. Internal battery or external power into jam input. |
|
INPUT:
Reads down to 0.3 volts (-10dB)
10K OHM DC Load impedance. |
 |
STABILITY: High stability TCXO crystal. +/-1ppm from -30 to +75°C |
|
|
|
|
|
|
|
|
| |
|
|
|
The Dcode® SB-3 is designed to replace the Dcode SB-2A in the Denecke line of Time Code Generators. The SB-3 reads, generates and jams to all the standard frame rates including 23.976 for High Definition shoots. The outputs include Time Code and Word Clock. The Temperature Compensated Crystal Oscillator (TCXO)
ensures low drift and very low Word Clock jitter.
|
|
|
|
|
|
|
|
|
| |
|
|
|
|